Komatsu — CONTROL AND ADJUSTMENT OF THE FAN BELT TENSION

TESTING AND ADJUSTMENTS CONTROL AND ADJUSTMENT OF THE FAN BELT TENSION CONTROL AND ADJUSTMENT OF THE FAN BELT TENSION 1. Checking the tension 1 - Depressthe belt (1)at thecentre of thesectionbetween the alternator (2) and the pulley (3) that drives the water pump. Check the flexion. Ata pressure of10kg(98N)theflexionshould be10–15 mm. If this value is not found, adjust the belt tension. # With a new belt the flexion should be 7–9 mm. 4 2 RKSA0070 2. Adjusting the belt tension 1 - Loosen the screws (4) that secure the alternator (2) 3 2 - Rotate the alternator (2) to give the belt (1) the correct tension and tighten the screw (4). 10 15 mm 3 - Check the belt (1) tension.

# If the belt has been replaced with a new one, check the tension again after about 20 hours of operation. 2 Screw: 25 32 Nm Crankshaft pulley 1 RKS01691 20-18 SK714-5 SK815-5