Komatsu — PPC VALVES

REMOVAL AND INSTALLATION PPC VALVES REMOVAL OF THE PPC VALVES Lower the working equipment until it is resting on the ground, stop the engine and remove the ignition key. 2 Release residual pressures from all circuits and from the tank. (For details, see «20. TESTING AND ADJU- STMENTS»). 6 1 1 - Raise the switch-box cover (1) disconnect the con- nectors (2) and remove the cover (1). 3 2 - Disconnect the protective sleeve (3). # Take care not to damage the frame (4). 4 3 - Loosen the four screws (5) and remove the casing (6). 5 RKSA0690 4 - Take out the three screws (7) and disconnect the PPC valve (8) from the support (9).

5 - Disconnect the six pipes (10) from the PPC valve and plug the tubes to prevent entry of impurities. # Check the marks on the tubes to avoid exchanging them during re-assembly. 9 7 1 8 INSTALLATION OF THE PPC VALVES 10 RKSA0700 To install, reverse removal procedure. 1 # Check very carefully the positions for the pipe con- nections. L.H. PPC VALVE LEFT-HAND PPC VALVE P T P 2 P 4 P 3 RKSA0710 P 1 RIGHT-HAND PPC VALVE R.H. PPC VALVE STANDARD R.H. AND L.H. PPC VALVES PATTERN CHANGE P 2 P T If the union pieces are dismantled from the PPC valves, make surethataunionwith afilterismountedatthePin- let.

P 4 P 3 P 1 RKSA0720 30-34 SK714-5 SK815-5 Position P T P1 P2 P3 P4 M White S White A Yellow R Yellow L Blue R Blue Posizione P T P1 P2 P3 P4 M White S White D Red S Red C Yellow A Yellow