Inspection of pre-lift a. If the nozzle tester handle is released with the needle valve engaged in a full lift condition, the tester pressure drops, being accompanied by decrease in the needle valve lift value (indicated value on the dial gauge). b. Take the indicated value on the dial gauge at the point of time when the sec- ondary spring completes its operation and the needle valve puts an end to descent (the position of needle valve lift value “ ” as shown in the above and right figures) and check that the value is with- in the specified limit. Measuring point for pre-lift Take the indicated value on the dial gauge at a point of primary opening pressure + approx. 1 0 kgf•cm 2 . Note :
Locate the point of primary opening pressure + approx. sure. 10kgf•cm 2 while dropping the pres- - 113 - 200 300 100 400 500 0 kgf / cm2 EQM4049I L lift of Amount 0 Tester pressure EQM4050I EQM4051I L lift of Amount 0 Primary opening pressure Tester pressure EQEQMM44005520I EQEQMM44005520I