. OPERATION MACHINE OPERATIONS AND CONTROLS Check Fuel Level, Add Fuel WARNING 1. Open fuel filler cap (F) of the fuel tank. 2. When fuel filler cap (F) is opened, float gauge (G) comes up in proportion to the remaining fuel level in the tank. Check that the fuel tank is full. Inspect the fuel level both visually and with float gauge (G). 3. If the fuel tank is not full, add fuel through the fuel filler until float gauge (G) rises to the maximum position. Fuel tank capacity: 1360 liters (359.31 US gal) Position of tip (a) of float gauge (G) when fuel tank is full: Approx 50 mm (2 in) 4.
After refilling with fuel, push float gauge (G) straight down with fuel filler cap (F) and then tighten the cap securely. REMARK clogged, the pressure in the tank Check for Water and Sediment in Water Separator, Drain Water 1. Open the engine room door. 2. The water separator forms one unit with fuel pre-filter (1). 3. It is possible to judge the water level and amount of sediment by looking through transparent cap (2). If there is any water or sediment collected at the bottom, set a container to catch the drain water under drain hose (3). 4. Loosen drain valve (4) and drain the water. 5. When fuel starts to drain from drain hose (3), tighten drain valve (4) immediately. Tighteningtorque:
0.2 to 0.45 Nm (0.02 to 0.046 kgm, 0.1 to 0.3 lbft) 3 - 80 When adding fuel, never let the fuel overflow. This may cause a fire. If any fuel is spilled, wipe it up comp letely. Never bring flames near fuel because it is highly flamm able and dangerous. I f breather hole (1) in the cap is will drop and fuel will not flow.