DISTRIBUTION SYSTEMS - ELECTRICAL POWER SYSTEM 5. Wind a layer of vinyl insulation tape up to the grey cable cover at each end of the repair section. Make a paper trough, then apply silicon rubber compound (non hardening sealant) over the re- paired section up to the cover ends. Sufficient sealant must be used to fill the ends of the cut away area. 6 6. Allow the compound to cure then cover the area with insulating tape taking the tape well over each end of the repair. An overlap of at least 50 mm (2 inches) of tape at each end is necessary. 7. Check to ensure the repair is satisfactory and se- cure the repaired cable so that repeat damage is avoided. NOTE: This is a temporary repair only.
Ensure the damaged cable is replaced as soon as possible to prevent ingress of water or chemicals. 7 Harness Wire Replacement If a wire within the harness is found to be beyond repair or is open circuit, a jumper wire may be installed as a temporary repair until such time when a new harness assembly can be installed. Use the following procedure to install an additional wire: 1. Locate the faulty wire using the procedures described in the fault code charts. 2. Disconnect the affected connectors. 3. If fitted carefully roll back the seal between the connector and harness outer covering. 4.
Remove the pins from the connector blocks of the affected wire using the appropriate removal tool found in the harness repair kit. NOTE: Use the instructions supplied with the kit to ensure correct pin removal. 8 A.30 / 5G