DISTRIBUTION SYSTEMS - ELECTRICAL POWER SYSTEM 5. From the harness repair kit select the correct pin for the connectors. Obtain locally the correct cross-sectional size wire and measure out the length required by following the harness routing. 6. Join the new wire to the new pins as described in the harness repair kit and install one of the pins into its connector. 7. If possible attempt to run the new wire within the existing harness outer covering, if this is not possible run the wire along the harness, securing regularly with suitable ties. With the wire correctly routed install the second terminal into its connector block. Replace the connector seal if removed. 8.
To ensure that the repair has been effective check for continuity of the new wire using a suitable multi-meter. NOTE: This is a temporary repair only. Ensure the damaged cable is replaced as soon as possible to prevent ingress of water or chemicals. 9 A.30 / 5H