Case IH AFX8010 — ELECTRICAL POWER SYSTEM

DISTRIBUTION SYSTEMS - ELECTRICAL POWER SYSTEM Measuring Voltage (Volts): Set the range dial to either ac or dc volts. Connect the Black test probe to the “COM” terminal and the Red test probe to the “V/ Ω ” terminal. Place the test probes across the component to be measured with the circuit complete (closed). Read off the display value. 13 Measuring Current (Amps): Set the range dial to either ac or dc current. When measuring current up to 2 amps, connect the Red test probe to the terminal. When measuring current up to 10 amps, connect the Red test probe to the 10 terminal. Always connect the Black test probe to the terminal.

When taking measurement of current, always break the circuit and connect the multi meter in series with the circuit. Read off the display value. NOTE: For protection, multi meters are usually fused at 10A. 14 Measuring Resistance (Ohms): Set the range dial to the desired Q position. Connect the Red test probe to the “V/ Ω ” terminal. Connect the Black test probe to the terminal. If the resistance being measured is connected in a circuit, then turn off the power to the circuit. Connect the test probes to the measuring point and read off the display value. 15 A.30 / 5J