Case IH AFX8010 — USER PLATFORM

BODY AND STRUCTURE - USER PLATFORM POWER SEAT SYSTEM CIRCUIT TROUBLESHOOTING Before troubleshooting the seat system make sure that the following operating conditions are met: A. The batteries are fully charged and all connections are clean and tight. B. Transmission in neutral or park. C. Check all connectors for full installation, loose, corroded, pushed out, or bent terminals. D. Check fuse F16. NOTE: The batteries must be fully charged and all connections clean and tight. Use a multimeter (DVOM) for these tests. For battery testing and service, see the battery section in the service manual. CAUTION DO NOT use a self-powered test light for any of these tests.

Use of a self-powered test light can cause damage to components in this system. WARNING Before performing any of the electrical tests, be sure all operating controls are in neutral or park lock position. This will eliminate accidental movement of the machine or start-up of power driven equipment. E.34 / 5 Symptom Possible Cause Reference/Test Height adjustment not operating Power and ground supply B - Height Adjustment Circuit Test Seat Pump Motor Seat Solenoid Air system leaking Check air lines for leakage