CROP PROCESSING - STORING AND HANDLING Grain storing 7. Pressure check the gearbox assemblies by pressurizing them with air through a fitting (1) applied to the remaining open plug hole to 0.35 bar ( 5 psi ) and submerge in a water tank. Use a gauge with full-scale reading of 100 - 200 kPa ( 15 - 30 psi ) to be able to read small changes in pressure that would indicate a leak. Be sure the gauge and fitting threads are well sealed to avoid a false indication of a leak. By watching the gauge or by using a manometer (scale of about 0.6 bar [ 8.6 psi ]), watch for a pressure drop over a ten minute period. This will verify the sealing integrity of the gearbox.
Dry the gearboxes and remove the level plugs (on the seam) (2) and fill the gearboxes with approximately 0.5 L ( 0.53 US qt ) of CASE AKCELA HY-TRAN ULTRA oil. Install all plugs and tighten to 9.6 Nm ( 87 lb in ). 20041759A5 7 9716 1 27/05/2004 K.60.B / 9