DISTRIBUTION SYSTEMS - ELECTRICAL POWER SYSTEM Alternator - Problem solving (A.30.A.82 - G.40.A.30) AFX8010 OPERATION The Alternator (B+) connector X213 is connected to the battery via terminal B+ on the Starter Motor and is grounded to the engine through connector X213 . The Alternator is self exciting and does not require an excitation circuit. Charging system output is controlled by an integral voltage regulator/brush assembly. The regulator is set to 14.2 volt regulation. The Alternator is temperature compensated so that output will drop as the Alternator warms up. TROUBLESHOOTING Before troubleshooting the charging system, make sure that the following conditions are met: 1.
The batteries are fully charged and all connections are clean and tight. 2. Transmission in neutral or park. 3. Check all connectors for full installation, loose, corroded, pushed out, or bent terminals. NOTE: The batteries must be fully charged and all connections clean and tight. Use a multi-meter (DVOM) for these tests. For battery testing and service, see the battery section in the service manual. IMPORTANT: Do not use a self-powered test light for any of the following tests. Use of a self-powered test light may cause damage to the components of this system. WARNING M980 - Before performing any of the electrical tests, be sure all operating controls are in neutral or park lock position.
This will eliminate accidental movement of the machine or start-up of power driven equipment. Alternator - Testing (A.30.A.82 - G.40.A.20) AFX8010 9667 1 27/05/2004 A.30.A / 303 Problem Possible Cause Correction System not charging or Charging poorly. Battery goes dead. Alternator Belt slipping or failed Replace alternator belt. Inspect tensioner assembly. B+ Circuit Alternator - Testing (A.30.A.82 - G.40.A.20) Alternator Alternator - Testing (A.30.A.82 - G.40.A.20) System overcharging Alternator Alternator - Testing (A.30.A.82 - G.40.A.20) N° Test Point Expected Result Other Result (Possible Cause) 1 Transmission in "Park" Start Engine and set to 1200 RPM. Measure voltage at battery.
12.8 - 14.5 volts If good reading, charging system is operating properly. High resistance between battery and B+ terminal at Alternator. Go to test 2 2 Place Negative Lead of multimeter to battery positive terminal and positive terminal to starter B+ terminal. Check voltage. Less than 0.4 volts If good reading, Go to test 3 High Resistance between Battery and starter B+ terminal. Repair/replace wiring as needed. 3 Attach positive lead of multimeter to B+ terminal of alternator and negative lead to starter B+ terminal. Read voltage. Less than 0.4 volts If good reading, Go to test 4 High Resistance in circuit 802 (RD). Repair/replace wiring as needed.