DISTRIBUTION SYSTEMS - LIGHTING SYSTEM Front work light - Overview (A.40.A.16 - C.10.A.10) AFX8010 Description The Front Work Lights are controlled by the Work Light Switch (S-43) found on the upper left switch panel. When the Key Switch (S-02) is in the "Start" or "Run" positions, current flows from pin 6, energizes the Cab Power Relay (K-26) and travels through the Cab Fuse Relay (F-49), to reach pin 2 of the Work Light Switch (S-43). The Work Light Switch (S-43) is a toggle switch with three positions: 1ST POSITION (OFF) Wiring harness - Electrical schematic frame 40 (A.30.A.88 - C.20.E.40) When the Work Light Switch (S-43) is in the first position, current flow is stopped. NOTE:
To reduce the possibility of blinding other drivers, some Front Work Lights are disabled when the combine is "Road Mode" or the Hazard Switch (S-25) is in the "On" Position. Both modes are explained below. 2ND POSITION When the Work Light Switch (S-43) is in the SECOND position, current flows from pin 3 and travels through connector X002 to reach connector X018 pin J1-3 of CCM-1. Depending on the positions of the On The Road Switch (S-12) and the Hazard Switch (S-25), current is sent to the following work lights:
On The Road Switch (S-12) and Hazard Switch in the "OFF" position Cab Outer Work Lights (E-15, E16) - Wiring harness - Electrical schematic frame 41 (A.30.A.88 - C.20.E.41) When the Work Lights Switch (S-43) is activated, CCM-1 sends current from connector X018 pin J1-11 to reach pin 86 of the Cab Roof Work Lights Relay (K-01). The relay energizes and latches terminals 30 and 87. Current sent from the electrical buss bar passes through the Cab Roof Light Fuse (F-31) and the Cab Roof Work Lights Relay and is split into two paths: The first path sends current through the LH Cab Roof Light Fuse (F-06), connector X002 , and connector X036 to reach pin A of the LH Cab Outer Work Light (E-15).
The ground path exits pin B and passes through a wire splice and connector X036 to reach the cab roof ground location #4. This causes the LH Cab Roof Light to illuminate. The second path sends current through the RH Cab Roof Light Fuse (F-07), connector X002 , and connector X036 to reach pin A of the RH Cab Outer Work Light (E-16). The ground path exits pin B and passes through a wire splice and connector X036 to reach the cab roof ground location #4. This causes the RH Cab Roof Light to illuminate.
Cab Inner Work Lights (E-17, E-18) High Beam - Wiring harness - Electrical schematic frame 41 (A.30.A.88 - C.20.E.41) When the Work Light Switch (S-43) is activated, CCM-1 sends current from connector X018 pin J1-5 to reach pin 1 of the Road Lights Relay (K-27). The relay energizes and latches terminals 3 and 5. Current sent from the Distance Work Light Relay (K-21) passes through the Road Lights Relay (K-27) and travels through connectors X003 and X036 to reach a wire splice. The wire splice splits the current into two paths: The first path sends current to pin B of the LH Cab Inner Work Light (E-17).
The ground path to the LH Cab Inner Work Light exits pin C and travels through a wire splice and connector X036 to reach the cab ground location #4. This causes the LH Cab Inner Work Light to illuminate (High Beam). The second path sends current to pin B of the RH Cab Inner Work Light (E-18). The ground path to the RH Cab Inner Work Light exits pin C and travels through a wire splice and connector X036 to reach the cab ground location #4. This causes the RH Cab Inner Work Light to illuminate (High Beam).
Cab Mid Work Lights (E-19, E-20) - Wiring harness - Electrical schematic frame 40 (A.30.A.88 - C.20.E.40) When the Work Light Switch (S-43) is activated, CCM-1 sends current from connector X018 pin J1-5 to reach pin 1 of the Road Lights Relay (K-27). From pin 1, current flows to pin 1 of the Header Work Lights Relay (K-22). The relay energizes and latches terminals 3 and 5. Current flows from the electrical system buss bar and passes through the Header Work Lights Relay (K-22) and connectors X002 and X036 to reach a wire splice. The wire splice splits the current into two different paths: The first path sends current to pin B of the LH Cab Mid Work Light (E-19).
The ground path to the light exits pin A and travels through connector X036 to reach the Cab Roof ground location #4. This causes the LH Cab Mid Work Light to Illuminate. The second path sends current to pin B of the RH Cab Mid Work Light (E-20). The ground path to the light exits pin A and travels through connector X036 to reach the Cab Roof ground location #4. This causes the LH RH Mid Work Light to Illuminate. 9668 1 27/05/2004 A.40.A / 20