DISTRIBUTION SYSTEMS - LIGHTING SYSTEM Head light Wiring harness - Testing (A.40.A.11.88 - G.40.A.20) AFX8010 9668 1 27/05/2004 A.40.A / 34 N° Test Point Expected Result Other Result (Possible Cause) 9 Place Road Light Switch S-26 in the High Beam position. Measure voltage at Road Light Switch S-26 connector X256 (pin 4). 12 volts If good reading, Road Light Switch S-26 is working properly. Go to test 10 Short to ground on circuits 218 (YE), 43 (YE) and 191 (YE) between Road Light Switch S-26 connector X256 (pin 4) and High Beam Relay K-04 (pin 1) or High Beam Indicator. 10 Place Road Light Switch S-26 in the Hazard position. Measure voltage at Road Light Switch S-26 connector X256 (pin 1).
12 volts If good reading, Road Light Switch S-26 is working properly. Short to ground on circuit 173 (OR) between Road Light Switch S-26 connector X256 (pin 1) and K-02 Light Control Relay (pin 5). 11 Place Road Light Switch S-26 in the Low Beam. position. Measure voltage at Road Light Switch S-26 connector X256 (pin 7). 12 volts If good reading, Road Light Switch S-26 is working properly. Short to ground on circuits 169 (YE) between Road Light Switch S-26 connector X256 (pin 7) and Low Beam Relay K-05 (pin 1). N° Test Point Expected Result Other Result (Possible Cause) 1 Turn Road Light Switch S-26 to Low Beam position. Measure for 12 volts at Low Beam Relay K-05 (pin 5).
12 volts If good reading, Go to test 2 Perform Low Beam Relay Test. 2 Measure the voltage at LH Road Light E-13 connector X164 (pin B). 12 volts If good reading, Go to test 3 Open circuit 237 (PU) or 638 (PU) between Low Beam Relay K-05 (pin 5) and LH Road Light E-13 connector X164 (pin B). 3 Disconnect the LH Road Light E-13. Measure the resistance on circuit 642 (BK) between LH Road Light E-13 connector X164 (pin A) and ground. Less than 1 ohm. If good reading, replace the low beam bulb of the LH Road Light E-13. Open in circuit 642 (BK) between LH Road Light E-13 connector X164 (pin A) and ground. 4 Turn Road Light Switch S-26 to Low Beam position.
Measure for 12 volts at Low Beam Relay K-05 (pin 5). 12 volts If good reading, Go to test 5 Perform Low Beam Relay Test. 5 Measure the for 12 volts at RH Road Light E-14 connector X169 (pin B). 12 volts If good reading, Go to test 6 Open circuit 237 (PU) or 639 (PU) between Low Beam Relay K-05 (pin 5) and RH Road Light E-14 connector X169 (pin B) 6 Disconnect the RH Road Light E-14. Measure the resistance on circuit 643 (BK) between RH Road Light E-14 connector X169 (pin A) and ground. Less than 1 ohms If good reading, replace the low beam bulb of the RH Road Light E-14. Go to test 7 Open in circuit 643 (BK) between RH Road Light E-14 connector X169 (pin A) and ground.
7 Turn Road Light Switch S-26 to .High Beam. position. Measure for 12 volts at High Beam Relay K-04 (pin 5). 12 volts If good reading, Go to test 8 Perform High Beam Relay Test. 8 Measure the voltage at LH Road Light E-13 connector X164 (pin A). 12 volts If good reading, Go to test 9 Open circuit 186 (PU) or 640 (PU) between High Beam Relay K-04 (pin 5) and LH Road Light E-13 connector X164 (pin A). 9 Disconnect the LH Road Light E-13. Measure the resistance on circuit 642 (BK) between LH Road Light E-13 connector X164 (pin A) and ground. Less than 1 ohm. If good reading, replace the High beam bulb of the LH Road Light E-13.
Open in circuit 642 (BK) between LH Road Light E-13 connector X164 (pin A) and ground.