Case IH AFX8010 — LIGHTING SYSTEM

DISTRIBUTION SYSTEMS - LIGHTING SYSTEM Turn/hazard light Flasher unit - Unidentified failure (A.40.A.13.86 - G.30.B.46) AFX8010 E0201-11 - ISO/NASO Selection Context: The CCM2 module is used to control the hazard light operation, depending on which market area the combine is operating in. The "NASO" mode is factory -selected for combines being used in North America, while the "ISO" mode is factory-set for all other market areas. This ensures that the hazard light respond correctly to meet legal and homologation requirements. When "ISO" mode is selected, the CCM2 module will send a 12 volts signal to the flasher module A-05 to switch it into the ISO operating mode.

If a 12 volts signal is not applied, then the flasher module will operate in the "NASO" operating mode. Cause: The ISO/NASO Selection circuit is open, or shorted to ground. Possible failure modes: 1. Supply wiring damaged. 2. Flasher module A-05 failed. 3. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "LIGHTS" sort menu, and select "ISO/NASO SELECT". Change the drop-down list to "STATUS", and press the "OFF" button to change the circuit output to "ON". The "STATUS" screen should indicate "OK" is the circuit is working properly. A.

If the status screen indicates "ERROR", the circuit is open or shorted to ground. Continue with step 2 . 2. Turn the ignition key "OFF". Disconnect connector X255 from the flasher module A-05. Use a multimeter to check for continuity between the harness end of connector X255 pin 9 and chassis ground. Flex the steering column (SC) harness between the flasher module and connector X033 while making this check. There should not be any continuity to ground. B. If the status screen indicates "OK", the circuit is working properly. Continue with step 6 . A. If there is continuity to ground, continue with step 3 . B. If there is no continuity to ground, continue with step 4 . 3.

Disconnect connector X033 . Use a multimeter to check for continuity between the cab main (CM) harness end of connector X033 pin 10 and chassis ground. Flex the cab main (CM) harness between connector X033 and connector X015 while making this check. There should not be any continuity to ground. A. If there is no continuity to ground, there is a short to ground in the steering column (SC) harness between connector X033 and connector X255 wire 204 purple. Locate the short and repair. B. If there is continuity to ground, there is a short to ground in the cab main (CM) harness between connector X033 and connector X015 wire 204 purple. Locate the short and repair. 4.

Turn the key switch to the "ON" position. Enter the Universal Display Plus "DIAG" screen. Select the "LIGHTS" sort menu, and select "ISO/NASO SELECT". Press the "OFF" button to change the circuit output to "ON". Use a multimeter to check for 12 volts between the harness end of connector X255 pin 9 and chassis ground. There should be 12 volts . A. If 12 volts is not present, continue with step 5 . B. If 12 volts is present, continue with step 6 . 5. Turn the key switch to the "ON" position. Enter the Universal Display Plus "DIAG" screen. Select the "LIGHTS" sort menu, and select "ISO/NASO SELECT". Press the "OFF" button to change the circuit output to "ON". 9668 1 27/05/2004 A.40.A / 37