Case IH AFX8010 — LIGHTING SYSTEM

DISTRIBUTION SYSTEMS - LIGHTING SYSTEM 9668 1 27/05/2004 A.40.A / 59 N° Test Point Expected Result Other Result (Possible Cause) 7 Measure for 12 volts at Header Work Lights Relay K-22 (pin 3). 12 volts If good reading, Go to test 8 Open in circuit 62 (RD) between Header Work Lights Relay K-22 (pin 3) and Fuse #30. Short to ground in circuit 63 (PU), 258 (PU) or 257 (PU) between Header Work Lights Relay K-22 (pin 5) and Header Lights E-21 and E-22 connectors X167 and X162 (pin A). A short will cause Fuse #30 to blow. 8 Disconnect the Header Work Lights Relay K-22. Measure resistance on circuit 238 (BK) between Header Work Lights Relay K-22 (pin 2) and ground. Less than 1 ohms.

If good reading, replace Header Work Lights Relay. Open circuit 238 (BK) between Header Work Lights Relay K-22 (pin 2) and ground. 9 Place Key Switch S-02 in ON position. Close Work Light Switch S-43. Measure for 12 volts at Cab Roof Work Lights Relay K-01 (pin 87). 12 volts. If good reading, the relay is operating properly. Cab Work Lights Relay K-01. Adjacent circuits. Go to test 10 10 Measure for 12 volts at Cab Roof Work Lights Relay K-01 (pin 86). 12 volts If good reading, Go to test 11 Open or short circuit 190 (WH) between Cab Roof Work Lights Relay K-01 (pin 86) and CCM-1 (pin J1-11). See Service Manual for testing of CCM.

11 Measure for 12 volts at Cab Roof Work Lights Relay K-01 (pin 30). 12 volts If good reading, Go to test 12 Open circuit 22 (RD) between Cab Roof Work Lights Relay K-01 (pin 30) and Fuse #31. Short to ground in circuit 23 (OR) or 88 (OR) between Cab Roof Work Lights Relay K-01 (pin 87) and Mid/Outer Work Lights E-15, E-16, E-19 and E-20. A short will cause Fuse #31 to blow. 12 Disconnect the Cab Roof Work Lights Relay K-01. Measure resistance on circuit 154 (BK) between Cab Roof Work Lights Relay K-01 (pin 85) and ground. Less than 1 ohms. If good reading, replace Cab Roof Work Lights Relay K-01. Open circuit 54 (BK) between Cab Roof Work Lights Relay K-01 (pin 85) and ground.

13 Place Key Switch S-02 in ON position. Close Work Light Switch S-43. Measure for 12 volts at Cab Roof Work Light Relay K-01 (pin 86). 12 volts If good reading, the wiring has good continuity. Distance Work Lights Relay K-21. Adjacent circuits. Go to next test point. 14 Measure the voltage at Dis- tance Work Lights Relay K-21 (pin 1). 12 volts If good reading, Go to test 15 Open or short circuit 189 (WH) or 190 (WH) between Distance Work Lights Relay K-21 (pin 1) and CCM-1 (pin j1-11). See Service Manual for testing of CCM. 15 Measure for 12 volts at Distance Work Lights Relay K-21 (pin 3).

12 volts If good reading, Go to test 16 Open circuit 60 (RD) between Distance Work Lights Relay K-21 (pin 3) and Fuse #29. 16 Disconnect the Distance Work Lights Relay K-21. Measure the resistance on circuit 155 (BK) between Distance Work Lights Relay K-21 (pin 2) and ground. Less than 1 ohms. If good reading, replace Distance Work Lights Relay K-21. Go to test 17 Open circuit 155 (BK) between Distance Work Lights Relay K-21 (pin 2) and ground.