DISTRIBUTION SYSTEMS - LIGHTING SYSTEM Back light - Unidentified failure (A.40.A.24 - G.30.B.46) AFX8010 E0198-11 - Backlighting Context: The backlighting circuit is used to power the backlights in the HVAC module and all cab roof switches. Power is sent from the CCM2 module to the splice block C, W-03, in the cab roof. From there, power is distributed to all switches for backlighting. The backlighting circuits in each cab roof switch are grounded to the cab roof ground 4.
A short to ground between the module and any one of the switch backlights fed by this circuit will cause this error, while an open circuit must be between the CCM2 module and the splice block C, W-03, in order to generate this error. An open circuit between the splice block and one of the switches will result in that backlight not functioning, while the overall circuit will still perform properly. Cause: The backlighting lamps circuit is open, or shorted to ground. Possible failure modes: 1. Supply wiring damaged. 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" menu.. Select the "LIGHTS" sort menu, and select "BACKLIGHT".
Change the drop-down list to "STATUS", and press the "OFF" button to change the circuit output to "ON". The "STATUS" screen should indicate "OK" if the circuit is working properly. A. If the status screen indicates "ERROR", the circuit is open or shorted to ground. Continue with step 2 . B. If the status screen indicates "OK", continue with step 15 . 2. Turn the key switch to the "ON" position. Enter the Universal Display Plus "DIAG" menu.. Select the "LIGHTS" sort menu, and select "BACKLIGHT". Press the "OFF" button to change the circuit output to "ON". Use a multimeter to check for 12 volts between connector X015 pin J1-11 and chassis ground. There should be 12 volts . A.
If 12 volts is not present, the CCM2 module is not functioning properly. Reload the software in CCM2 module using the EST, and recheck the circuit operation. If the CCM2 module is still not providing 12 volts output, replace the module. B. If 12 volts is present, continue with step 3 . 3. Turn the key switch to the "OFF" position. Remove the HVAC controller from its DIN slot to provide access to the cab roof (CR) harness. Remove the cap/buss strip from the cab roof (CR) harness splice block C connector X133 . Use a multimeter to check for continuity between connector X133 pin B and chassis ground. There should not be any continuity to ground. A.
If there is continuity to ground, there is a short to ground in the cab main (CM) harness or cab roof (CR) harness between connector X015 pin J1-11 through connector X002 pin 18 to connector X133 pin B on one of the following wires; wire 231 purple, connector X015 pin J1-11 to cab main (CM) harness splice, wire 247 purple, cab main (CM) harness splice to connector X075 on accessory socket J-08, wire 206 purple, cab main (CM) harness splice to connector X070 on cigar lighter R-08, wire 232 purple, cab main (CM) harness splice to connector X002 pin 18, wire 232 purple, connector X002 pin 18 to connector X133 pin B. Locate the short and repair. B.
If there is no continuity to ground, continue with step 4 . 4. Turn the key switch to the "ON" position. Enter the Universal Display Plus "DIAG" menu.. Select the "LIGHTS" sort menu, and select "BACKLIGHT". Press the "OFF" button to change the circuit output to "ON". Use a multimeter to check for 12 volts between connector X133 pin B and chassis ground. There should be 12 volts . 9668 1 27/05/2004 A.40.A / 82