Case IH AFX8010 — ELECTRONIC SYSTEM

DISTRIBUTION SYSTEMS - ELECTRONIC SYSTEM TROUBLESHOOTING AN INDIVIDUAL MODULE ALARM There are two general conditions that may cause a “Not Detected” or “Communication Lost” alarm message for a module; loss of module power or ground, or CAN-related faults. Each module requires a power and ground supply to provide main operating power for the module; if either of these is lost, the module will power down and will not be active on the network. There are several possible CAN-related faults that may cause a module to go offline. External problems include bad or open connections to the CAN HI and CAN LO network wires as a result of damaged wiring.

Internal prob- lems may include a failure of the CAN controller itself (the device that actually does the “communicating” on the network), or the module may be “bussing off” due to excessive error messages. Whenever a module transmits or receives a faulty message, it keeps a record of that error. After its error history fills up, the CAN controller assumes that it is faulty, and will stop transmitting on the network (module has gone “Bus Off”); this will result in a “Communication Lost” alarm message. This error history is erased and reset at zero when the module is powered down. Troubleshooting Steps 1.

A quick way to verify if a module has a power and ground connection is to activate a function within that module that does not require other CAN message information (function is controlled entirely by affected module). If the function operates, then the module is powered up, and the alarm is due to a CAN fault. See available functions by module below. If the module that is offline is not listed below, continue with step 2. YMIU: Inspect the front of the module to determine if the green light is illuminated and flashing - this indicates the module is powered and functioning. CCM1: Turn on Road Lights or Work Lights. If lights come on, CCM1 is powered up and functioning. CCM2:

Depress brake pedal to activate brake lights. If lights come on, CCM2 is powered up and functioning. CCM3: Use remote Sieve Adjust switches to activate sieve actuators (if installed). If sieves operate, CCM3 is powered up and functioning. RHM: Turn key switch S-02 “OFF” and then “ON”. If speaker sounds, the RHM module is powered up and functioning. SSM: If it has power but no CAN, warning lights will flash in rotating sequence. A. If the module function operates, the module is powered up, and the fault is due to a CAN problem. Continue with step 3. B. If the module function does not operate, the module may not be powered up. Continue with step 2. A.50.A / 107