Case IH AFX8010 — ELECTRONIC SYSTEM

DISTRIBUTION SYSTEMS - ELECTRONIC SYSTEM 3. Testing has determined that the module is offline due to a CAN fault, either with the CAN controller inside the module, or with the physical wiring to the network. Use a multimeter to check for continuity between the two wires that connect the module to the network. NOTE: Several modules are connected to the network through internal solder paths on the circuit boards, and cannot be tested as described. These modules include the RHM, CCM1, CCM2, and the Engine Control Unit (GOV/ECU). If one of these modules are offline, continue with step 4. A.

If there is continuity between the two network wires, and the resistance measured is 60 ohms, the external wiring is okay, and the fault is internal to the module. Continue with step 4. B. If there is continuity between the two network wires, but the resistance is very high (> 70 ohms), there is a bad connection in the external wiring to the network. Check the harness and connectors for damage and repair as necessary. C. If there is no continuity between the two network wires, there is an open circuit in one of the two wires. Locate the open and repair. 4. CAN fault is internal to the module. Use the Electronic Service Tool to reload the correct version software in the module. A.

If module now functions properly, fault was due to corrupt software. Fault should be resolved. B. If module still remains offline after software is reloaded, the module has failed internally, and must be replaced to repair the fault.

A.50.A / 109 Module Network Connection Comments YMIU Connector X438 pin 1 wire 1251 yellow (CAN HI) and pin 2 wire 1252 green (CAN LO) • Connects to network at splice in expan- sion (EX) harness • Refer to schematic frame 31 GPS Connector X321 pin 4 wire 1241 yellow (CAN HI) and pin 2 wire 1240 green (CAN LO) • Connects to network at splice in main frame (MF) harness • Refer to schematic frame 31 CCM3 Connector X012 pin J1-14 wire 133 yellow (CAN HI) and pin J1-13 wire 134 green (CAN LO) • Connects to network at CCM2 connector X015 pins J1-20 (CAN HI) and J1-19 (CAN LO) • Refer to schematic frame 30 SSM Connector X320 pin 3 wire 1182 yellow (CAN HI) and pin 4 wire 1123 green (CAN LO) • Connects to splice in adapter display (AD) harness just before reaching connector X064 • Refer to schematic frame 30