DISTRIBUTION SYSTEMS - ELECTRONIC SYSTEM TROUBLESHOOTING MULTIPLE MODULE ALARMS If multiple alarm messages related to the network appear at once, this is an indication of problems with the net- work itself, instead of problems with a specific module. 1. Use a multimeter to check the resistance between pin D and pin C on connector X065. A. A reading of 0 ohms indicates that CAN HI (yellow wire) is shorted to CAN LO (green wire). Go to Data Bus - Short Circuit Troubleshooting. B. A reading of 120 ohms indicates an open circuit in either CAN HI (yellow wire) or CAN LO (green wire). Go to Data Bus - Open Circuit Troubleshooting. C. A reading of 60 ohms indicates that the network wiring is okay.
Continue with Step 2. 2. Remove the cover over the electrical connector on the bottom of the display module (ICDU). Unplug connector X319 from the bottom of the ICDU, and use a multimeter to check the resistance between connector X319 pin 7 & 8. There should be 60 ohms resistance. A. If there is infinite resistance, there is an open circuit in the adapter display (AD) harness between connector X319 and the splice near connector X064 wires 1171 yellow (CAN HI) and 1172 green (CAN LO). Locate the open and repair. B. If there is 60 ohms resistance, the ICDU has a good connection to the network. Refer to the troubleshooting for the individual alarm messages to correct the concern.
Data Bus - Short Circuit Troubleshooting 1. Open the service door on the right side of the cab. Disconnect connector X001 from the bottom of the right console. Use a multimeter to check the resistance between the cab main harness end of connector X001 pins 6 & 7. There should be 120 ohms resistance. A. If there is 0 ohms resistance, continue with step 2. B. If there is 120 ohms resistance, continue with step 4. 2. Remove the right cab A-post cover to expose the termination resistor R17. Remove the resistor plug, and use a multimeter to check the resistance between pins A & B of the resistor connector on the harness. A.
If there is infinite resistance, the termination resistor is shorted internally. Replace the resistor. B. If there is 0 ohms resistance, continue with step 3. 3. Disconnect connector X064 in the right cab post, and use a multimeter to check the resistance between the cab main harness end of connector X064 pins A & E. A. If there is infinite resistance, there is a short in the adapter display (AD) harness between connector X064 and the termination resistor connector in the following wires:
Wire 143 yellow, connector X064 pin A to AD harness splice Wire 1173 yellow, AD harness splice to AD harness splice Wire 1207 yellow, AD harness splice to resistor connector pin B Wire 144 green, connector X064 pin E to AD harness splice Wire 1174 green, AD harness splice to AD harness splice Wire 1208 green, AD harness splice to resistor connector pin A Locate the short and repair. B. If there is 0 ohms resistance, there is a short in the cab main (CM) harness between connector X064, connector X001 and connector X065 in the following wires:
Wire 143 yellow, connector X064 pin A to CM harness splice Wire 271 yellow, CM harness splice to connector X065 pin C Wire 127 yellow, CM harness splice to connector X001 pin 6 Wire 144 green, connector C064 pin E to CM harness splice Wire 270 green, CM harness splice to connector X065 pin D Wire 128 green, CM harness splice to connector X001 pin 7 Locate the short and repair. A.50.A / 110