Case IH AFX8010 — ELECTRONIC SYSTEM

DISTRIBUTION SYSTEMS - ELECTRONIC SYSTEM 12. Remove the jumper wires from the cab main half of connector X015. Use a multimeter to check for continuity between connector X001 pins 8 & 9. A. If there is no continuity, there is a short in the cab main (CM) harness between connector X012 and connector X015 wires 133 yellow and 134 green. Locate the short and repair. B. If there is continuity, continue with step 13. 13. Disconnect the cab roof harness from the cab main harness at connector X003 (it will be necessary to remove the upper trim panel in the cab to gain access to this connector). Install jumper wires on the cab main end of connector X003 between pins 1 & 4 and between pins 2 & 6.

Use a multimeter to check for continuity between connector X001 pins 8 & 9. A. If there is no continuity, there is a short in the cab roof (CR) harness between connector X142, connector X159 and connector X003 on one of the following pairs of wires: Wires 999 yellow and 996 green from connector X142 pins 2 & 4 to CR harness splice. Wires 807 yellow and 806 green from connector X159 pins 2 & 7 to CR harness splice. Wires 131 yellow and 132 green from connector X003 pins 1 & 2 to CR harness splice. Wires 137 yellow and 138 green from CR harness splice to connector X003 pins 4 & 6. Locate the short and repair. B. If there is continuity, continue with step 14. 14.

Remove the jumper wires from the cab main half of connector X003. Use a multimeter to check for continuity between connector X001 pins 8 & 9. A. If there is no continuity, there is a short in the cab main (CM) harness between connector X015 and connector X003 wires 131 yellow and 132 green. Locate the short and repair. B. If there is continuity, continue with step 15. 15. Disconnect the cab main harness from the CCM1 module at connector X018. Install jumper wires on the cab main end of connector X018 between pins J1-13 & J1-19 and between pins J1-14 & J1-20. Use a multimeter to check for continuity between connector X001 pins 8 & 9. A.

If there is no continuity, there is a fault in the CCM1 module. Replace the module. B. If there is continuity, continue with step 16. 16. Remove the jumper wires from the cab main end of connector X018. Use a multimeter to check for continuity between connector X001 pins 8 & 9. A. If there is no continuity, there is a short in the cab main (CM) harness between connector X003 and connector X018 wires 137 yellow and 138 green. Locate the short and repair. B. If there is continuity, there is a short in the cab main (CM) harness between connector X018 and connector X001 wires 129 yellow and 130 green. Locate the short and repair. Data Bus - Open Circuit Troubleshooting 1.

Open the service door on the right side of the cab. Disconnect connector X001 from the bottom of the right console. Use a multimeter to check the resistance between the cab main harness end of connector X001 pins 6 & 7. There should be 120 ohms resistance. A. If there is infinite resistance, continue with step 2. B. If there is 120 ohms resistance, continue with step 4. 2. Remove the right cab A-post cover to expose the termination resistor R17. Remove the resistor plug, and use a multimeter to check the resistance between pins A & B of the resistor plug. A. If there is infinite resistance, the termination resistor is open internally. Replace the resistor. B.

If there is 120 ohms resistance, continue with step 3. A.50.A / 112