Yanmar — Yanmar Diesel Inboard Shop Manual for One, Two, and Three Cylinder Engines

LAY -UP AND FITTING OUT 65 5. Loosen the cover screws on the seawater pump (Fig- ure 3, typical) and drain any water in the pump. lf thc gas- ket is damaged. remove the cover and install a new gasket and the cover. 6. Allow the cooling system to drain completely, then close all drains. 4 Adding ant if reeze The following procedure pertains to seawater cooling systems and is designed to provide additional protection against damage due to freezing temperatures while the boat is in storage. C.AUTION Do not nm the engine after perfo rming the storage service procedure tnat fotlows. Be- fore returning the hoat to service, drain the seawater cooling system as described in this chapter. I.

Refer to Chapter Eight to remove the thermostat and gasket. Discard the gasket. 2. Make sure the scacock or water inlet to the seawater pump is closed . 3. Pour a 50/50 solution of pure soft water and ethylene glycol antifreeze through the thermostat hole into the en- gine until the cylinder head, block and manifold arc full, 4. Reinstall the thermostat with a new gasket. Heat - -'l- -T ~ ' exc hanger Fr eshwater (Closed) Cooling Syste m The freshwater section ofa cooling system need not be drained during winter months, provided it is filled with a 50/50 solution of pure soft water and ethylene glycol anti- freeze.

However, if draining the freshwater cooling sys· tern is necessary, usc the following procedure. Note that the following procedures address the freshwa- ter and seawater sections of the cooling system separately. If the freshwater portion is not being drained, follow the draining procedure for the seawater section. 2. On 3GM, 3GM30, 3HM and 3HM35 engines, open the drain on the underside of the exhaust manifold (Fi !!: ure 1, typical). 3. Open the drain on the cylinder block (Fig ur e 2, typi- cal). 4. Remove the lower end of all cooling system hoses from the engine, pump and exhaust manifold. Lower the hoses and allow them to completely drain. Reconnect the hoses and clamp securely.

Freshwater (cl oud) cooli ng section I. Place containers under the drains, if space permits. This will prevent coolant from draining into the bilge. 2. Remove the pressure fill cap from the heat exchanger (Figure 4). ,VOTE On IGM and IGMIO engines. access is re- stricted to the upper water pump cover sere",·: If a suitable tool is not available, it may be necessary to remove the cranksha ft pulley jor access to afl of the water pl/mp cover screws. WARNING Ethylene glycol is WI environmental toxic waste that cannot he legally flushed down a drain or poured on the ground. Put it in suit-