With the vibration set to both drums, valves SVR1 , SV3 and SV2 need to be electrically controlled. Valve SVR1 disposes of a pressure relief protection function which opens at a pressure of 180 bar and releases the oil fl ow to the tank. If the vibration is set to the front drum only, valve SV1 is electrically activated and valve SV2 is deactivated. The vibration drive unit at the rear drum is decelerated by the shutoff valve RV1 . If the vibration at the front or the combined front/rear vibration is turned off, all valves are electrically deactivated and the vibration drives are delerated by the shutoff valve V1 . Vibration system 8 - 6 Issue: 01-10 8.1.5 Overview:
Control block vibration RV1 SV3 Y04 Y03 Y05 SV1 SVR1 3 Y06 SV2