56 SEBU7901-01 Maintenance Section Cooling System Coolant (DEAC) - Change 7. Reinstall the belt guard. Allow the coolant to drain. If new drive belts are installed, check the drive belt tension again after 30 minutes of engine operation at the rated rpm. NOTICE Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant.
i02070334 Cooling System Coolant (DEAC) - Change For information regarding the disposal and the recycling of used coolant, consult your Caterpillar dealer or consult Caterpillar Dealer Service Tools: SMCS Code: 1350-070; 1395-044 Outside Illinois: 1-800-542-TOOL Inside Illinois: 1-800-541-TOOL Canada: 1-800-523-TOOL Clean the cooling system and flush the cooling system before the recommended maintenance interval if the following conditions exist: The engine overheats frequently. Flush Foaming of the coolant 1. Flush the cooling system with clean water in order to remove any debris. The oil has entered the cooling system and the coolant is contaminated. 2. Close the drain valve (if equipped).
Clean the drain plugs. Install the drain plugs. Refer to the Specifications Manual for your particular engine for more specific information on the proper torques. Refer to the Specifications, SENR3130, “Torque Specifications” for more general information on the proper torques. The fuel has entered the cooling system and the coolant is contaminated. NOTICE Use of commercially available cooling system clean- ers may cause damage to cooling system compo- nents. Use only cooling system cleaners that are ap- proved for Caterpillar engines. NOTICE Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks. Note:
Inspect the water pump and the water temperature regulator after the cooling system has been drained. This is a good opportunity to replace the water pump, the water temperature regulator and the hoses, if necessary. 3. Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add .5 L (1 pint) of cleaner per 15 L (4 US gal) of the cooling system capacity. Install the cooling system filler cap. Drain 4. Start the engine and run the engine at low idle for a minimum of 30 minutes. The coolant temperature should be at least 82 °C (180 °F). Pressurized System: Hot coolant can cause seri- ous burns.
To open the cooling system filler cap, stop the engine and wait until the cooling system components are cool. Loosen the cooling system pressure cap slowly in order to relieve the pres- sure. NOTICE Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal com- ponents. To avoid damage to the cooling system, make sure to completely flush the cooling system with clear wa- ter. Continue to flush the system until all signs of the cleaning agent are gone. 1. Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. 2.
Open the cooling system drain valve (if equipped). If the cooling system is not equipped with a drain valve, remove one of the drain plugs.