SEBU7901-01 59 Maintenance Section Cooling System Coolant (ELC) - Change For information regarding the disposal and the recycling of used coolant, consult your Caterpillar dealer or consult Caterpillar Dealer Service Tools: 1. Fill the cooling system with Extended Life Coolant (ELC). Refer to the Operation and Maintenance Manual, “Refill Capacities and Recommendations” topic (Maintenance Section) for more information on cooling system specifications. Do not install the cooling system filler cap. Outside Illinois: 1-800-542-TOOL Inside Illinois: 1-800-541-TOOL Canada: 1-800-523-TOOL Flush 2. Start the engine and operate the engine at low idle. Increase the engine rpm to high idle.
Operate the engine at high idle for one minute in order to purge air from the cavities of the engine block. Stop the engine. 1. Flush the cooling system with clean water in order to remove any debris. 2. Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to the Specifications Manual for your particular engine for more specific information on the proper torques. Refer to the Specifications, SENR3130, “Torque Specifications” for more general information on the proper torques. 3. Pour more ELC into the cooling system until the cooling system is full. 4. Clean the cooling system filler cap. Inspect the gasket that is on the cooling system filler cap.
If the gasket that is on the cooling system filler cap is damaged, discard the old cooling system filler cap and install a new cooling system filler cap. If the gasket that is on the cooling system filler cap is not damaged, use a 9S-8140 Pressurizing Pump in order to pressure test the cooling system filler cap. The correct pressure for the cooling system filler cap is stamped on the face of the cooling system filler cap. If the cooling system filler cap does not retain the correct pressure, install a new cooling system filler cap. NOTICE Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks. 3. Fill the cooling system with clean water.
Install the cooling system filler cap. 4. Start the engine and run the engine at low idle until the temperature reaches 49 to 66 °C (120 to 150 °F). 5. Loosen the cap for the coolant recovery tank slowly in order to relieve any pressure. Remove the cap for the coolant recovery tank. 5. Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. Open the drain valve (if equipped) or remove the cooling system drain plugs. Allow the water to drain. Flush the cooling system with clean water. Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs.
Refer to the Specifications Manual for your particular engine for more specific information on the proper torques. Refer to the Specifications, SENR3130, “Torque Specifications” for more general information on the proper torques. 6. Pour Extended Life Coolant (ELC) into the coolant recovery tank until the coolant reaches the “COLD FULL” mark. DO NOT fill the coolant recovery tank above the “COLD FULL” mark. 7. Clean the cap for the coolant recovery tank. Install the cap for the coolant recovery tank. 8. Start the engine. Inspect the cooling system for leaks and for proper operating temperature.
Engines that are NOT Equipped with a Coolant Recovery Tank Fill Engines that are Equipped with a Coolant Recovery Tank NOTICE Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks. NOTICE Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks. 1. Fill the cooling system with Extended Life Coolant (ELC). Refer to the Operation and Maintenance Manual, “Refill Capacities and Recommendations” topic (Maintenance Section) for more information on cooling system specifications. Do not install the cooling system filler cap.