SEBU7901-01 69 Maintenance Section Engine Air Cleaner Service Indicator - Inspect Inspecting the Primary Air Cleaner Elements Do not use paint, a waterproof cover, or plastic as a protective covering for storage. An airflow restriction may result. To protect against dirt and damage, wrap the primary air cleaner elements in Volatile Corrosion Inhibited (VCI) paper. Place the primary air cleaner element into a box for storage. For identification, mark the outside of the box and mark the primary air cleaner element. Include the following information: Date of cleaning Number of cleanings Store the box in a dry location.
g00281693 Illustration 31 Inspect the clean, dry primary air cleaner element. Use a 60 watt blue light in a dark room or in a similar facility. Place the blue light in the primary air cleaner element. Rotate the primary air cleaner element. Inspect the primary air cleaner element for tears and/or holes. Inspect the primary air cleaner element for light that may show through the filter material. If it is necessary in order to confirm the result, compare the primary air cleaner element to a new primary air cleaner element that has the same part number. i01900118 Engine Air Cleaner Service Indicator - Inspect (If Equipped) SMCS Code:
7452-040 Some engines may be equipped with a different service indicator. Do not use a primary air cleaner element that has any tears and/or holes in the filter material. Do not use a primary air cleaner element with damaged pleats, gaskets or seals. Discard damaged primary air cleaner elements. Some engines are equipped with a differential gauge for inlet air pressure. The differential gauge for inlet air pressure displays the difference in the pressure that is measured before the air cleaner element and the pressure that is measured after the air cleaner element. As the air cleaner element becomes dirty, the pressure differential rises.
If your engine is equipped with a different type of service indicator, follow the OEM recommendations in order to service the air cleaner service indicator. Storing Primary Air Cleaner Elements If a primary air cleaner element that passes inspection will not be used, the primary air cleaner element can be stored for future use. The service indicator may be mounted on the air cleaner housing or in a remote location. g00281694 Illustration 32 g00103777 Illustration 33 Typical service indicator