MACHINE OPERATIONS AND CONTROLS OPERATION 5. To return the setting so that it measures the depth from the ground surface, turn mode selector switch (1) to the depth display 0 set mode position, then turn setting switch (2) to the CLEAR position. The display will return to the depth display measured from the ground surface. REMARK When carrying out the measurement, place the bucket in the same posture at the measurement point as it was at the standard surface. If the starting switch is turned OFF in the mode set condi- tion, the mode set condition is canceled. Setting depth mode When the boom is lowered to the desired set depth, it will auto- matically stop. 1.
Turn mode selector switch (1) to the depth mode position. 2. Lower the boom to the position to be set. 3. Turn setting switch (2) to the SET position. The buzzer will sound twice and indicator (3) will light up. 4. If the boom is raised, then lowered again, it will stop at the set point. REMARK The stop position may differ slightly as follows according to the operating conditions. If the boom is lowered slowly, the boom will stop slightly before the set position. In cold weather, it may go beyond the set position before stopping, so be sure to carry out the warming- up operation thoroughly to warm up the hydraulic oil before starting operations.
For details of the warming up the procedure, see "WARMING-UP OPERATION (PAGE 3-60)". In the depth mode, the amount the boom can be lowered is set. The arm and bucket cannot be set, so operations such as automatic horizontal digging cannot be carried out. 3-100