Bobcat 325/328 Excavator — 6902610-325-328 om 3-06(8).book

SPARK ARRESTER SILENCER Figure PM-40 Cleaning Procedure See the SERVICE SCHEDULE for the correct service interval. (See SERVICE SCHEDULE on Page 59.) Do not operate the excavator with a defective exhaust system. IMPORTANT 1 This excavator is factory equipped with an approved spark arrester silencer. It is necessary to do maintenance on this spark arrestor muffler to keep it in working condition. The spark arrester silencer must be serviced by dumping the spark chamber every 100 hours of operation. P-49437 Remove the plug (Item 1) [Figure PM-40] from the bottom of the silencer.

Start the engine and run for about 10 seconds while a second person, wearing safety glasses, holds a piece of wood over the outlet of the silencer. The carbon deposits will be forced out of the silencer plug hole (Item 1) [Figure PM-40] . If this machine is operated on flammable forest, brush or grass covered land, it must be equipped with a spark arrester attached to the exhaust system and maintained in working order. Check local laws for spark arrester requirements. I-2061-0195 Stop the engine. Install and tighten the plug. Close the tailgate. WARNING When the engine is running during service, the steering columns must be in neutral. Failure to do so can cause injury or death.

W-2203-0595 Stop the engine. Open the tailgate. 325/328 Excavator Operation and Maintenance Manual 80