Cummins — Cummins CM2220 R2.8 Installation Guide R101B

R2.8 CM2220 R101B Starting the Engine Section 2 - Start-Up and Troubleshooting Page 2-3 Coolant CAUTION The cooling system must be filled properly to prevent air locks. During filling, air must be vented from the engine coolant passages. Wait 2 to 3 minutes to allow air to be vented; then add mixture to bring the level to the top. To make sure air is vented from the cooling system during the fill process: The thermostat has provisions that allow air to vent through the thermostat when the thermostat is closed. NOTE: There is a manual bleed vent plug on the exhaust gas recirculation (EGR) cooler coolant return line. To help purge air from the system, open this vent while filling the system.

Close the bleed vent plug after filling the system. The system has a design fill rate of 11 liters [3 gal] per minute. Figure 5 - Thermostat Air Vent Never use water alone for coolant. Damage from corrosion can be the result of using water alone for coolant. CAUTION Use a mixture of 50 percent water and 50 percent ethylene glycol or propylene glycol antifreeze to fill the cooling system. Refer to Procedure 018-004 in Section V for coolant recommendations and specifications. Refer to Procedure 387-008 in Section 1 for cooling system capacities. Figure 6 - Mix and Fill Coolant Do not remove the pressure cap from a hot engine.

Wait until the coolant temperature is below 50°C [122°F] before removing the pressure cap. Heated coolant spray or steam can cause personal injury. NOTE: Make sure the manual bleed vent plug on the EGR cooler coolant return line is closed before operating the engine. WARNING Install the pressure cap. The coolant level will drop once the coolant is circulated in the system during engine running. Have coolant available to replenish the system of the purged air. To buy Cummins Parts and Service Manuals, Training Guides, or Tools go to our website at https://store.cummins.com