Cummins — Cummins CM2220 R2.8 Installation Guide R101B

R2.8 CM2220 R101B Starting the Engine Section 2 - Start-Up and Troubleshooting Page 2-5 Starting WARNING Do not use starting fluids with this engine. This engine is equipped with an intake air heater: use of starting fluid can cause an explosion, fire, personal injury, severe damage to the engine and property damage. Disengage the driven unit, or if equipped, put the transmission in neutral. With the accelerator pedal or lever in the idle position, turn the keyswitch to the ON position. Figure 9 - Starting Pedal and Transmission Position With the key in the ON position, the engine indicator lamps will come on momentarily and then go out. The engine indicator lamps include:

2 STOP (or STOP ENGINE) lamp, red in color 1 WARNING (or CHECK ENGINE) lamp, amber in color 3 ENGINE MALFUNCTION or MALFUNCTION INDICATOR LAMP (MIL) 4 WAIT-TO-START lamp. The WAIT-TO-START lamp will remain on for a minimum of 5 seconds and a maximum of 30 seconds, based on coolant and air temperature while the grid heater cycles. If any of the lamps remain on or begin to flash, reference the J1939 CAN display for fault code information and visit Cummins® QuickServe® Online (QSOL) for troubleshooting information. Once the WAIT-TO-START lamp turns OFF, turn the key to the starting position to start the engine.

Do not engage the starting motor for more than 30 seconds or damage to the starting motor can result. Wait 2 minutes between each attempt to start (electrical starting motors only). CAUTION The engine must have adequate oil pressure within 15 seconds after starting. If the WARNING lamp indicating low oil pressure has not gone out or there is no oil pressure indicated on a gauge within 15 seconds, shut OFF the engine immediately to avoid engine damage. CAUTION Once the engine starts, immediately check the oil pressure gauge and indicator lights.

If all indicating lights are OFF and adequate oil pressure is present, continue to idle the engine for 3 to 5 minutes, monitoring the condition of the engine and looking for any fluid leaks that may be present. After the minimum idle time and a thorough review of the installation, load and engine speed can be slowly increased while continuing to monitor the condition of the engine. Continue this process until the thermostat opens, enabling coolant to flow throughout the system while checking for fluid leaks. To buy Cummins Parts and Service Manuals, Training Guides, or Tools go to our website at https://store.cummins.com