Bobcat Company 442 — Identification

COMPONENTS (S/N 528911001 & ABOVE AND 52864001 & ABOVE) Figure 70-51-3 Identification Figure 70-51-1 1 2 P-63305 1 Receiver/Drier: The receiver/drier (Item 1) [Figure 70-51- 3] is the unit that receives the liquid refrigerant from the condenser and removes moisture and foreign matter from the system. It also serves as a storage tank for the extra liquid refrigerant until it is needed by the evaporator. P-63303 Compressor: The compressor (Item 1) [Figure 70-51-1] is the pump that circulates the refrigerant throughout the system. It raises the pressure of the refrigerant for heat transfer through the condenser and evaporator. Pressure Switch:

The pressure switch (Item 2) [Figure 70-51-3] will disengage the compressor clutch at high pressure readings on the high side, or at low pressure on the high side, which indicates loss of refrigerant. NOTE: The A/C system (compressor) is recommended to be turned on for at least five minutes weekly throughout the year to lubricate the internal components. Figure 70-51-4 Figure 70-51-2 1 1 P-63306 Heater Unit: The heater unit (Item 1) [Figure 70-51-4] is located under the operator seat in the excavator cab. The unit delivers warm air for heat into the cab. The unit contains the blower, heater coil and thermostat. P-63304 Condenser:

The condenser (Item 1) [Figure 70-51-2] is the unit that receives the high pressure, high temperature refrigerant vapor from the compressor and condenses it into a high temperature liquid. 442 Excavator 70-51-1 Service Manual