BASIC TROUBLESHOOTING (CONT’D) Figure 70-80-30 Checking The Electrical System (Cont’d) Figure 70-80-28 1 1 P-63624 2 If there is voltage at the harness, check the resistance at the pressure switch (Item 1) [Figure 70-80-30] . P-63622 Disconnect the wire harness (Item 1) from the pressure switch (Item 2) [Figure 70-80-28] . If there is no resistance value, check for low or high refrigerant levels in the system. (See Gauge Pressure Related Troubleshooting on Page 70-100-2.) Figure 70-80-29 If a resistance value is observed, the pressure switch is good. If there is no voltage at the wiring harness check the harness for broken wires.
If there are no broken wires, reconnect the wire harness to the pressure switch. Early Models Tilt the cab. ((See Tilting The Cab on Page 10-160-2.).) 1 Figure 70-80-31 P-63623 Using a multimeter check the wiring harness (Item 1) [Figure 70-80-29] for voltage. The voltage should be approximately 12 volts. 1 P-63616 Remove the hose (Item 1) [Figure 70-80-31] . 442 Excavator 70-80-9 Service Manual