BASIC TROUBLESHOOTING (CONT’D) Figure 70-80-34 Checking The Electrical System (Cont’d) Figure 70-80-32 1 1 P-63625 The resistance value of the thermostat should be 10 Ohms at 68 ° F (20 ° C), between Pin 8 & Pin 9 on the electrical connector (Item 1) [Figure 70-80-34] . (Between the yellow wire and green wire) P-63578 Disconnect the thermostat/blower fan wire harness (Item 1) [Figure 70-80-32] . If there is no resistance value, replace the thermostat. ((See THERMOSTAT on Page 70-190-1.).) Figure 70-80-33 If there is no voltage at the wiring harness check the harness for broken wires. 1 If there are no broken wires use the following procedure to check the blower fan and switch.
Figure 70-80-35 P-63625 1 Check the wire harness (Item 1) [Figure 70-80-33] for voltage. The voltage should be approximately 12 volts, from Pin A4 (yellow wire) to ground. If there is no voltage at the wiring harness, check the harness for broken wires. P-63578 If there is voltage at the wiring harness, check the thermostat for resistance. Disconnect the wire harness (Item 1) [Figure 70-80-35] . 442 Excavator 70-80-10 Service Manual