Bobcat Company 442 — Checking The Electrical System

BASIC TROUBLESHOOTING (CONT’D) Figure 70-80-37 Checking The Electrical System (Cont’d) Figure 70-80-36 1 1 P-63626 If there is voltage at the wiring harness, check the resistance to the blower fan at the thermostat/blower fan wiring connector (Item 1) [Figure 70-80-37] . P-63627 Check the wire harness (Item 1) [Figure 70-80-36] for voltage to the blower fan. Check the resistance between Pin 2 (brown wire) and Pin 10 (blue wire). In the cab, place the blower switch in position 1. Check for voltage at the harness connector (Item 1) [Figure 70- 80-36] , Pin 10. (Green/blue wire). The voltage should be 12 volts. Check the resistance between Pin 2 (brown wire) and Pin 9 (black wire).

Check the resistance between Pin 2 (brown wire) and Pin 8 (red wire). In the cab, place the blower switch in position 2. Check for voltage at the harness connector (Item 1) [Figure 70- 80-36] , Pin 9. (green/gray wire). The voltage should be 12 volts. If there is no resistance value at any of these pins, replace the blower fan. ((See HEATER/AC FAN on Page 70-20-1.).) In the cab, place the blower switch in position 3. Check for voltage at the harness connector (Item 1) [Figure 70- 80-36] , Pin 8. (Green/black wire). The voltage should be 12 volts. If there is resistance value at any of the pins, check the climate controls at the control panel inside the excavator cab.

If there is no voltage at the wiring harness, check the harness for broken wires. 442 Excavator 70-80-11 Service Manual