Bobcat Company 442 — Pump Testing

HYDRAULIC PISTON PUMP (S/N 522311001 & ABOVE) (CONT’D) Curl the bucket until the bucket cylinder is fully extended and the relief valve opens. Pump Testing (Cont’d) Record the pressure. Back-up Relief Valve Adjustment The pressure at the gauge (Item 2) [Figure 20-50-11] should be 4350 PSI (300 bar). Figure 20-50-10 Stop the engine. Figure 20-50-12 1 1 P-33368 Turn the load sense adjustment screw (Item 1) [Figure 20-50-10] in 3/4 of a turn, increasing the relief pressure approximately 600 PSI (41,4 bar) to 4660 PSI (321 bar).The load sense relief is now set to a higher pressure than the back-up relief. P-33369 Remove the plastic cap (Item 1) [Figure 20-50-12] .

Figure 20-50-13 Figure 20-50-11 1 2 2 1 P-33370 P-33366 Install a 5000 PSI (345 bar) pressure gauge on the test coupler (Item 1) [Figure 20-50-11] . Loosen the lock nut (Item 1) [Figure 20-50-13] . Turn the adjustment screw (Item 2) [Figure 20-50-13] in to increase pressure and out to decrease pressure. Start the excavator and warm the hydraulic oil to operating temperature. NOTE: One quarter turn is approximately 200 PSI (13,8 bar). Move the engine speed control to the high speed position. Tighten the nut and retest the back-up relief valve. 442 Excavator 20-50-8 Service Manual