RECONDITIONING THE ENGINE (S/N 522311001 & ABOVE) (CONT’D) Figure 60-80-95 Assembly (Cont'd) Install the glow plugs. (See Glow Plug Removal And Installation on Page 60-50-4.) Lightly oil and install a new O-ring on the shutoff solenoid. Press and hold the control rod in the stop position. Figure 60-80-93 P-61952 Install the injectors [Figure 60-80-95] . NOTE: The return line fitting must face the exhaust side. Figure 60-80-96 P-61950 Install the shutoff solenoid [Figure 60-80-93] . Figure 60-80-94 P-61953 Install the clamps and start the bolts. Do not tighten the bolts at this time [Figure 60-80-96] . P-61951 Install and tighten the bolts to 15 ft.-lb. (21 N•m) torque [Figure 60-80-94] .
Lightly grease and install a seal on the injectors. 442 Excavator 60-80-26 Service Manual