Komatsu — SWITCHES

OPERATION Emergency Pump Drive Switch Remark This switch is provided to enable you to carry out operation temporarily, when any problem occurs on the pump control system. Do not use it except in emergency. Furthermore, remove the cause of the problem immediately. Remark If this switch is depressed and moved to the EMERGENCY position by mistake, thereby engaging the machine in the work, while the machine is in normal condition, an "E02" mark is shown in the display. If "E02" is displayed during the work, check that the switch is in the NORMAL position.

This switch (9) makes it possible to carry out operations for a short time when there is a failure in the pump control system (when the display is “E02”). (a) When abnormal: . . . . . . . . . . . . . . . . . . . . . Switch pushed up (b) When normal: . . . . . . . . . . . . . . . . . . . . . Switch pushed down If the display is “E02”, push this switch up to make it possible to carry out operations. Swing Brake Cancel Switch Remark This switch makes it possible to perform swing operations for a short time even when there is a problem in the swing brake electric system. DO NOT use this switch except in emergencies. Repair the problem as soon as possible.

This switch (10) makes it possible to carry out swing operations for a short time when there is a failure in the swing brake system (when the display is “E03”). (a) When abnormal: . . . . . . . . . . . . . . . . . . . . . Switch pushed up (b) When normal: . . . . . . . . . . . . . . . . . . . . . Switch pushed down If the display is “E03”, push this switch up to make it possible to carry out operations. When this switch is pushed up, the swing lock monitor flashes. Revolving Warning Lamp Switch (if equipped) Use this switch (11) to light up the yellow rotating lamp on top of the cab. (a) ON: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lamps light up (b) OFF: . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lamps go off 2-78 PC200LC-8