Komatsu — Phenomena that are Not Failures

OPERATION TROUBLES AND ACTIONS Running out of Fuel When starting after running out of fuel, fill with fuel and bleed the air from the fuel system before stating. For details on bleeding the air, see “Replace Fuel Pre-Filter Cartridge” on page 3-62, “Replace Fuel Main Filter Cartridge” on page 3-75. Procedure for Bleeding Air 1. Loosen the knob of feed pump (1), pull it out, then pump it in and out until the movement becomes heavy. Remark It is not necessary to remove the plug at the top of the fuel pre-filter and fuel main filter. 2. Push in the knob of feed pump (1) and tighten it. 3. Turn the key in the starting switch to the START position and start the engine.

When doing this, do not crank the starting motor continuously for more than 20 seconds. If the engine does not start, wait for at least two minutes, then try again. Perform this operation a maximum of four times. Phenomena that are Not Failures Note that the following phenomena are not failures: When the arm control lever is operated to the IN position and the work equipment is lowered under no load from a high position, the arm speed will drop momentarily when the arm is more or less at the vertical position. When the bucket is empty and digging operations are carried out from above, the movement will momentarily become slow when the bucket teeth are almost perpendicular.

The bucket or arm will fluctuate by itself during heavy-duty digging operations. When starting or stopping the swing, noise will be emitted from the brake valve. When going down a steep slope at low speed, a noise will be emitted from the travel motor brake valve. 2-196 PC200LC-8