MAINTENANCE 5. With the lock lever at the FREE position (F), operate the work equipment control levers fully in the LOWER direction and check that the work equipment is lowered to the ground. 6. If the work equipment goes down under its weight and contacts the ground, the accumulator is normal. If the work equipment does not go down or stops midway, the charged pressure of the gas in the accumulator for the hydraulic circuit has probably dropped. Please contact your Komatsu distributor for inspection. 7. This completes the inspection. After completion of the inspection, set the lock lever to the LOCK position and turn the starting switch to the OFF position.
Method of Releasing Pressure in Hydraulic Circuit 1. Place the work equipment on the ground. Close the crusher attachment jaws, etc. 2. Operate the work equipment lock lever to the LOCK position. 3. Insert the lock pin for the attachment control pedal in position (c) where it is possible to operate the pedal. (if equipped) 3-82 PC200LC-8