MAINTENANCE Carry out Steps 4 - 6 within 15 seconds. When the engine is stopped, the pressure in the accumulator gradually goes down. For this reason, the check can only be carried out immediately after the engine is stopped. 4. Stop the engine. 5. Turn the starting switch to the ON position (B). 6. Set lock lever to FREE position (F), then operate the work equipment control levers and the attachment control pedal (if equipped) fully to the front, rear, left, and right to release the pressure in the control circuit. 7. Set the lock lever to the LOCK position, then turn the starting switch to the OFF position. 8.
Insert the lock pin in position (a) so that the attachment control pedal cannot be operated. (if equipped) Check Alternator The brushes may be worn or the bearing may have run out of grease, contact your Komatsu distributor for inspection and repairs. If the engine is started frequently, have this inspection carried out every 1000 hours. Check Engine Valve Clearance, Adjust Special tools are needed for inspection and maintenance, please contact your Komatsu distributor. PC200LC-8 3-83