OPTIONS, ATTACHMENTS HYDRAULIC CIRCUIT Remark • The return circuit when a breaker is installed must return directly to the return filter, so do not use it except in B mode. • The standard set pressure for the service valve safety valve is set when the machine is shipped from the factory. When B mode is selected, it is set to 210 kgf/cmІ (2980 psi); when ATT mode is selected, it is set to 280 kgf/cmІ (3980 psi). Depending on the attachment, adjustment may be necessary. In such a case, please ask your Komatsu distributor to carry out the adjustment. Switching Hydraulic Circuit Depending on the type of attachment, set the working mode on the monitor as follows.
The set pressure of the service valve safety valve and the hydraulic circuit switch is according to the working mode selected. Adjusting Oil Flow Depending on the attachment, it is necessary to change the oil flow in the service circuit. For details of setting the oil flow, see “ATTACHMENT OPERATIONS” on page 5-21. Switching Between Breaker and General Attachment When optional attachment is installed and working mode is set to B mode. (1) Forms breaker circuit (one-way circuit). (2) Hydraulic oil flowing through breaker circuit passes through additional filter for breaker. (3) Relief valve is set to low pressure. When shipped from factory: 210 kgf/cm 2 (2980 psi).
(4) Maximum oil flow can be adjusted in user mode. When optional attachment is installed and working mode is set to ATT mode. (1) Forms crusher circuit (double-acting circuit). (2) Hydraulic oil flowing through crusher circuit does not pass through additional filter for breaker. (3) Relief valve is set to high pressure. When shipped from factory: 280 kgf/cm 2 (3980 psi). (4) Maximum oil flow can be adjusted in user mode. 5-8 PC200LC-8 Attachment Working mode Hydraulic circuit Set pressure of service safety valve One-way circuit attachment, such as breaker B mode Automatically forms circuit where return circuit does not pass through control valve When shipped from factory:
210 kgf/cm2 (2980 psi) Double-acting circuit attachment, such as crusher ATT mode Automatically forms circuit where return circuit passes through control valve When shipped from factory: 280 kgf/cm2 (3980 psi)