Komatsu — Replace Additional Breaker Filter Element

OPTIONS, ATTACHMENTS 9. Clean the removed parts, then install new element (2). Element (2) must be installed facing in the correct direction. Set direction Y with the holes in it facing up, and insert the hole in element (2) on the protruding portion inside filter head (6). 10. Install O-ring (4) to filter case (1), then screw filter case (1) to filter head (6). When the top of filter case (1) contacts the filter head, tighten it at least a further 1/2 turns. 11. Clean plug (3), then fit a new O-ring (5) to plug (3). 12. Install plug (3) to filter case (1). Torque: . . . . . . . . . . . . . . . . . . . 27.4 - 58.8 N·m (20.3 - 43.4 lb/ft) PC200LC-8 5-13