Komatsu — Attachment Installation

OPTIONS, ATTACHMENTS 7. Loosen slowly oil filler cap (F) on top of the hydraulic tank to eliminate the internal pressure in the hydraulic circuit. 8. After confirming low oil temperature, remove the plug from the outlet and inlet port respectively. Take care that no dust, mud etc. adheres to the hose mouse piece portions. If O-ring is damaged, replace it with a new one. 9. Connect the hose at the attachment side. When doing this, check the direction of flow of the oil and be careful not to make any mistakes. 10. Set the rotor of the stop valve installed to the inlet port on the side face of the arm and the outlet port piping to FREE position (a). (a) FREE:

Hydraulic oil flows (direction of arrow is parallel to long direction of arm) (b) LOCK: Hydraulic oil does not flow (direction of arrow is at right angles to long direction of arm) When setting the FREE or LOCK position of the stop valve rotor, remove bolt (2), turn over plate (1), then turn the rotor. After setting, install plate (1) again with bolt (2). 11. After installing the attachment, check the oil level in the hydraulic tank. 5-20 PC200LC-8