Komatsu — When Using Breaker

OPTIONS, ATTACHMENTS If the working mode pilot monitor does not display B for the breaker mode, press working mode selector switch (1) and set to the breaker mode as follows. When working mode selector switch (1) is pressed, the screen switches to the working mode selection screen. 1. Press working mode selector switch (1) or press switches F3 or F4 to select breaker mode B. 2. With breaker mode B highlighted in yellow, do one of the following to accept the selection. Keep working mode selector switch (1) pressed. Press switch F6. Leave as it is for five seconds. 3. If the breaker mode is selected, “Really Set Breaker Mode?” is displayed on the screen.

To set to the breaker mode, press switch F6. If switch F5 is pressed, the screen returns to the working mode selection screen without changing to the breaker mode. If a slide arm or other special attachment is installed and the mode is switched to the breaker mode by mistake, it may lead to serious danger, such as the work equipment suddenly dropping. If breaker operations are carried out in a mode other than the breaker mode, the warning screen is displayed. Always carry out breaker operations in the breaker mode 5-22 PC200LC-8