MAINTENANCE SECTION 5 Page 25 ELECTRIC SYSTEM 5.10.2. AUTOMATIC RESET CIRCUIT BREAKER Electric circuits are protected by automatic reset circuit breakers mounted on the underside of the instrument panel. In the event of a short circuit or ground, the circuit breaker will open and close until trouble clears or is corrected. The circuit breaker will then return and stay in its normal closed position. 5.10.3. BATTERIES General Batteries can only be charged using receptacle located close to the engine on the left hand side of the machine. The receptacle can also be used to connect additional source of supply, e.g. for engine starting.
This receptacle can also be used to connect additional source of power to start the engine under extreme conditions. Fig. 5.11. Location of Batteries A machine is equipped with two 12-volt battery. They are located in L.H. fender. Access is provided upon removal of three bolts and lifting the cover. Never allow a battery to stand on concrete, ground or a metal support unless proper insulation is provided. A wooden platform or board is a sufficient insulation. Be sure the battery in a machine is fastened securely to avoid damage from vibration. WARNING! A battery gives off highly flammable gas. Never allow sparks, open flame or lighted smoking material near the battery.
Avoid spilling any electrolyte on hands or clothing. Always wear safety glasses when working on a battery. WARNING! Never check a battery charge by placing a metal object across the terminals. The sparks could cause a battery explosion. Use a voltmeter or hydrometer to measure the charge. WARNING! Be sure the electric system master switch is off when connecting or disconnecting a battery to minimize the chance of sparks and explosion. DRESSTA TD-15H