DRESSTA Co. Ltd. TD-15H — 5.11.4. CHECKING THE CONDITION OF FAN AND HUB

MAINTENANCE SECTION 5 Page 31 ENGINE 6. Mark the position of the vibration damper (Fig. 5.19) and rotate the camshaft by 360 [є]. Check and adjust (step 2), if necessary, the other valves as shown in Fig. 5.20 as described in item 5 above. Fig. 5.19. Vibration Damper Position Mark Fig. 5.20. Engine Valves (Step 2) I. Intake Valves E. Exhaust Valves 7. Install the valve cover. IMPORTANT: Use the same cover gasket unless it is damaged. If so, replace it with a new one. 8. Torque the valve cover bolts to 24 [Nm]. 9. Reinstall all the parts removed in step 2 and 1. 5.11.4. CHECKING THE CONDITION OF FAN AND HUB Check the fan hub every 1000 hours of operation.

It should rotate freely although without excessive loose. If the end play exceeds 0.15 [mm] the hub bearing should be replaced. DRESSTA TD-15H