DRESSTA Co. Ltd. TD-15H — 5.11.6. ETHER INJECTOR (IF EQUIPPED)

SECTION 5 MAINTENANCE Page 32 ENGINE 5.11.5. INSPECTION OF IDLER PULLEY Idler pulley should be checked every 1000 hours of operation. The pulley should rotate freely but without excessive play. Fig. 5.21. Inspection of Idler Pulley 5.11.6. ETHER INJECTOR (if equipped) Precautions WARNING! Ether starting fluid is highly flammable. Follow the precautions on the container. Explosion can result if sparks or flame contact ether or a container is stored in temperature above 70 [°C]. Observe the following precautions: Do not use the ether injector when air temperature is above 0 [°C]. Do not use open flame when using ether-starting fluid. Do not store fluid containers in the operator's compartment.

Store containers in a cool, well ventilated place. Keep fluid containers out of unauthorized personnel. Do not breathe hazardous ether vapor. Do not let ether contact your skin, because it can cause frostbite. Never puncture a fluid container or put it into fire. Dispose of empty containers properly. For your safety, remove the ether container when welding, grinding, or using a torch on a machine. Follow the correct method of starting the engine. Refer to "STARTING THE ENGINE" in this manual. IMPORTANT: An ether starting valve inlet must be sealed against the entry of dirt at all times by having a fluid container installed or by installing the dust cap provided with the valve. TD-15H DRESSTA