SECTION 5 MAINTENANCE Page 38 HYDRAULIC SYSTEM Fig. 5.29. Hydraulic Reservoir Drain Plug IMPORTANT: Use clean oil from a clean container. Maintain all packaging and fittings so as to prevent leakage. 6. Reinstall the drain plug. Fill the reservoir with lubricant up to the center line of the sight gauge. Refer to Section 6 "REFILL CAPACITIES" for the quantity oil specified. Reinstall the filler cap. 7. Vent the system. Refer to "VENTING THE HYDRAULIC SYSTEM". 5.13.3. SERVICING THE RETURN FILTER NOTE: The hydraulic reservoir does not have to be drained in order to service this filter. IMPORTANT:
If the filter warning light on the instrument panel, remains on at the operating oil temperature with the engine running, the filter must be changed. Change the hydraulic return filter as described below: 1. Park the machine on level ground, lower the blade to the ground and stop the engine. Turn the electric master switch to OFF. 2. With the engine stopped, operate the equipment lever several times in all directions to relieve any pressure. Remove the return filter side cover located on the R.H. side in front of the hydraulic reservoir, remove all outside dirt from the filter. 3. Using a filter wrench, remove the filter. Wipe the filter head, removing all of the old oil from the seal area.
4. Coat the seal on the new filter element with clean oil. Install the new element by threading it onto the filter head until the seal contacts the head, turn the filter by hand an additional 1/4 to 1/2 turn. Check the oil level in the system as outlined in "CHECKING OIL LEVEL". TD-15H DRESSTA