SECTION 5 MAINTENANCE Page 40 HYDRAULIC SYSTEM WARNING! Always lower all mounted equipment to the ground before performing work on the hydraulic system. With all mounted equipment lowered to the ground and the engine off, operate the equipment lever several times in all directions to relieve any pressure. 5. Install the suction strainer, secure it with the nut. Install the reservoir cover with a new O-ring. 6. Fill the system, refer to "CHANGING HYDRAULIC OIL". 5.13.5. SERVICING THE RESERVOIR BREATHER Fig. 5.32. Hydraulic Reservoir Breather Location 1. Park the machine on level ground, lower the blade to the ground and stop the engine.
Turn the electric master switch to OFF and remove the key. With the engine stopped, operate the equipment lever several times to relieve any pressure. Remove all outside dirt from the breather. 2. Slowly loosen the filler plug on the reservoir in order to relieve any pressure in the reservoir. CAUTION! Pressurized Reservoir. Always loosen the filler plug slowly in case there is still some pressure in the system. 3. Remove the breather (Fig. 5.33) from the reservoir. Remove snap ring (1), cover (2), element (3) and clean in nonflammable commercial solvent. Dry thoroughly. Check O-ring (4) for wear or deterioration. Replace if necessary. Reinstall the filter and cover.
Secure with snap ring (1). Reinstall the breather and the filler cap. TD-15H DRESSTA