DRESSTA Co. Ltd. TD-15H — 5.14. LUBRICATING FITTINGS

MAINTENANCE SECTION 5 Page 41 HYDRAULIC SYSTEM Fig. 5.33. Hydraulic Reservoir Breather 1. Snap Ring 2. Element Cover 3. Breather Element 4. O-Ring 5.13.6. VENTING THE HYDRAULIC SYSTEM The hydraulic system has to be vented of air if: the system has been drained and filled, the hydraulic lines have been disconnected or tightened, after noting hydraulic leaks, the hydraulic system has been operated with excessively low oil level. 1. Start the engine and run it at low idle speed. Operate all the controls through all positions four or five times so the cylinders are filled with oil and air expelled. 2. Check the oil level as described in "CHECKING OIL LEVEL".

Repeat this procedure until the fluid level remains at the specified level in the reservoir. 5.14. LUBRICATING FITTINGS GENERAL The following lubrication fittings are to be greased at the intervals indicated in the "SCHEDULED MAITENANCE GUIDE". brake and engine control linkage (8 fittings), hand steering levers (2 fittings), DRESSTA TD-15H