DRESSTA Co. Ltd. TD-15H — 5.18.1. UNIVERSAL JOINTS

SECTION 5 MAINTENANCE Page 50 FINAL DRIVES Fig. 5.43. Checking the Lubricant Level 1. Filler and Level Plug 2. Drain Plug 5.17.2. CHANGING THE OIL 1. While the oil is at operating or warm ambient temperature, park the machine on level ground. Remove drain plugs (2) and levels plugs (1) and allow the lubricant to drain into a suitable container. Remove metal particles from the magnetic plugs. Install and tighten the drain plugs. Fill app.8 liters of fuel oil up to the housing and install the plugs. 2. Operate the machine in low gear (with no load) for a few minutes. Remove the drain plugs and thoroughly drain the fuel oil into a suitable container. Reinstall and tighten the drain plugs.

Remove the filler and level plugs. Fill the housing with fresh oil up to the bottom of the filler and level plug opening. Refer to the "REFILL SPECIFICATIONS AND CAPACITIES" chart, 5.3.1 for grade of lubricant specified. Reinstall and tighten the filler and level plugs. 5.18. TRANSMISSION SYSTEM 5.18.1. UNIVERSAL JOINTS Every 500 hours lubricate the universal joints of transmission system. General The rear frame is the common oil reservoir for the transmission, torque converter and hydraulic steering drive. The system has a pressure filter and a suction strainer, which require service. TD-15H DRESSTA