Perkins — Perkins 4.108 4.107 4.99 Diesel Engine Workshop Manual

ELECTRICAL EQUIPMENT-Q.2 Any variance in the above data could indicate a fault and the following procedure should be adopted before disconecting any components. The regulator is a sealed unit and is non-repairable and if found to be faulty it must be replaced. 4. Fault Finding on 11 AC If the alternator does not produce its rated output of 43 amperes for 12 volt and 23 amperes for 24 volt circuit, the failure may be due to any unit or the associated wiring, and the following procedure should be followed. Warning Lamp does not light when switched "On". TEST 1 Check the bulb.

Checking the Field Isolating Relay If no fault Disconnect the earthed battery terminal and the cable from the alternator main output terminal. Connect a 0-60 DC ammeter between the terminal and dis- connected cable. Link terminals 'C1' and 'C2' on the field relay. Reconnect the battery cable. Close the master switch and start engine and run at charging speed. If ammeter shows a charge the relay is faulty, or its wiring and connections. If ammeter shows no charge, carryon with Test 2. Check all wiring connections at regulator, alternator and battery. If no fault Switch off, disconnect 'F' lead at regulator and connect it to the negative terminal. Switch on.

If warning lamp lights up, the regulator is faulty. If lamp fails to light up, the alternator is faulty. TEST 2 Checking the Alternator and Control Box Leave the test ammeter connected, and disconnect cables 'F' and '-' from control unit and join them together. Remove link from field relay terminals and ensure they are connected to 'C1' and 'C2'. Start engine and run at charging speed. Ammeter should indicate current values at 35 amps or more for 12 volt circuit or 22 amps or more for 24 volt circuit. A zero or low reading indicates a faulty alterator. If satisfactory output is recorded, a faulty control unit is indicated.

Warning Lamp does not go out and Ammeter shows no output when running. Check all regulator, alternator and battery connections. If no fault Switch off, disconnect 'F' lead at regulator and connect to regulator negative terminal. Switch on, and run at fast idle. If no output, alternator is faulty. If output appears, regulator is faulty. TEST 3 Checking or Adjusting the Voltage Setting The regulator of the 4 TR control unit must be set on CLOSED CIRCUIT, when the alternator is under load. Also, the system must be stabilised before checking or resetting is carried out, and the battery must be in a well charged condition.

Check the battery to control' unit wiring, to ensure that the resistance of the com- plete circuit does not exceed 0.1 ohm. Any high resist- ance must be traced and remedied. Connect a test DC voltmeter (suppressed zero type) scale 12 15 volts for 12 volt installations or 24-30 volts for 24 volt in- stallations, between the battery terminals, and note the reading with no electrical load. Disconnect battery earth cable and connect test ammeter between alter- nator main terminal and disconnected cable. Re- connect battery earth cable, and switch on an electrical load of approximately two amps, such as, side and tail lights. Start engine and run at about 2000 rev/min for at least eight minutes.

If the charging current is still greater than 10 amps, continue to run engine until this figure is reached. Then compare the voltmeter reading with the appropriate setting limits, as specified for the particular control unit as follows. Warning Lamp does not go out when running and Ammeter shows reduced output with full output only at maximum speed or Warning Lamp goes out but Alternator delivers reduced output. Full output only at maximum speed. Alternator faulty. Remove from installation and apply open circuit diode check. Warning Lamp flashes intermittently and Ammeter needle oscillates when Battery is fully charged and no loads are switched in.

Check for excessive resistance in regulator negative sensing lead. If no fault, regulator is faulty. Batteries overcharging and Ammeter indicates high or full output all the time. 12 V (37423)/(37449) 24 V (37444)/(37502) 12 V (37429) 13.9 - 14.3 volts 27.9 - 28.3 volts 13.7 -14.1 volts Check regulator positive sensing lead and its connec- tion at regulator. If no fault, regulator is faulty. (Part no. marked on upper edge of the moulded cover of Control Unit).